Hours of Operation:
M-F 8:15 - 5:00pm EST
Memorial Day: Closed Monday May 27, 2013


Note: Seal Minder relay and high temperature floats must be ordered for panels being used with high temperature pumps. Heat sensor connectors are standard on all panels.
SEAL MINDER: comes standard with the F-Series pumps.
(Specifications dependent on model & may change without notice)
| MAX. FLOW: GPM | 158 |
|---|---|
| MAX. HEAD: ft | 60' |
| PUMP TYPE | Sump, High Temperature |
| STRAINER OPENING | 0.5625" x 0.25" Slot |
| DISCHARGE SIZE | 3" NPT-M |
| DISCHARGE CONNECTION | ###TX_EXBJMPUMPSPRODUCTS_DISCHARGECONNECTION### |
| MAX. SUBMERGED DEPTH | 65' |
| MIN. SUBMERGED DEPTH | 9.5" |
| SHIPPING WEIGHT:lbs | 69 |
| MOTOR CASING | 304SS |
|---|---|
| PUMP VOLUTE | Cast Iron |
| IMPELLER - MULTI VANE | Cast Iron |
| STRAINER / STAND | ###STAND### |
| LIP SEALS & O-RINGS | FKM |
| ROTOR SHAFT | 304SS |
| EXTERNAL HARDWARE | 304SS |
| QTY. OIL IN SEAL CHAMBER | 9 U.S FL. OZ., SHELL FM 32, NSF APPROVED |
| QTY. OIL IN MOTOR STATOR | 35 U.S. FL. OZ., OIL-FILLED W/ SHELL FM 32, NSP APPROVED |
| PUMPTOPCOVER | ###TX_EXBJMPUMPSPRODUCTS_PUMPTOPCOVER### |
| PUMP HANDLE | ###TX_EXBJMPUMPSPRODUCTS_PUMPHANDLE### |
| MOTOR RATING: HP | 2 |
|---|---|
| MOTOR RPM | 3450 |
| MOTOR INSULATION CLASS | R |
| MOTOR SERVICE FACTOR | 1.1 |
| VOLTAGE | 208/230/460/575, 3ph- 60 Hz |
| CURRENT F.L.A. | 6.3 |
| MOTOR PROTECTION | Thermal Sensor Switches Embedded in Each Winding Phase |
| POWER CORD: GAGE; LENGTH | A.W.G. 16/4, 33', high temp. rated |
| MAXIMUM LIQUID TEMPERATURE | 200° F |
| Seal Minder® | STANDARD |
| HousePorts | ###HOSEPORTS### |
|---|---|
| Hydraulic Oil | ###HYDRAULICOIL### |
| HydraulicInputFlow | ###HYDRAULICINPUTFLOW### |
| HydraulicOperatingPressure | ###HYDRAULICOPERATINGPRESSURE### |